Version 1.311 (build 8)  -- RELEASE NOV 2023 --
 Full rebranding to Anybus.
 New menu layout:
  - Channel list is merged into "Home" page
  - Oscilloscope Errors is merged with dropdown in "Oscilloscope Images" page
  - "Diagnostic Slave info" has been renamed into "ProfiHub Diagnostics" 
  - "IP Configuration" has been merged with "General Configuration"
  - "E-mail accounts config" has been renamed into "E-mail configuration"
  - "E-mail & log event config" has been renamed to "Alarm Configuration"
  - "Output event configuration" has been merged with Alarm Configuration
  - "SNMP Event Config" has been renamed to "SNMP Configuration"
  - "Diagnostic Slave configuration" has been renamed to "ProfiHub Configuration" and is merged with "Network Configuration"
  - "User message" is merged with "Password & User configuration"
  - "Update License" has been renamed to "Licenses" 

********************************************************************************

Version 1.310 (build 1)  -- RELEASE MAY 2023 --
 Add support for the Lattice FPGA based headstation.

********************************************************************************

Version 1.309 (build 1)  -- RELEASE APRIL 2023 --
 Partial rebranding to Anybus.

********************************************************************************

Version 1.308 (build 1)  -- RELEASE JULY 2022 --
 Add support for the Xilinx XC6S-LX25-FT256 FPGA based headstation.
 When the Xilinx XC6S-LX25-FT256 FPGA is used there will be a fixed license.
 When the Xilinx XC6S-LX25-FT256 FPGA is used the following limitations are in place:
  - 3 networks (normally this is 4).
  - No support for CommDtm. 
  - no license update mechanism.
  - No support for ComBricks Profibus modules.
  - No support for ComBrick Profinet modules.

********************************************************************************

Version 1.307 (build 11)  -- RELEASE APRIL 2022 --

 Improvement: BxFOR+ Fiber optic signal & ring also apply to the FO-events.
 Fix: The Head Station master did not come online after a while, while switching between multiple networks.
 Fix: Input fields are now checked for special characters.
 Fix: Password security has been increased.
 Improvement: Logging has been added when the ComBricks is set to factory defaults.
 Improvement: Logging has been added when the ComBricks' password is changed or cleared.
 Improvement: Logging has been added when the user attempts to log in to the ComBricks.

********************************************************************************

Version 1.306 (build 0)  -- RELEASE JULY 2020 --

 Fix: Stability issue at startup fixed

********************************************************************************

Version 1.305 (build 0)  -- RELEASE JUNE 2020 --

 Fix: Fix is SNMP library

********************************************************************************

Version 1.304 (build 9)  -- RELEASE MAY 2020 --

 Fix: Updated the IP-stack

********************************************************************************

Version 1.303 (build 2)  -- RELEASE NOVEMBER 2019 --

 Fix: SNMP library bug fix
 Improvement: Overall speed improvement
 Improvement: Message recorder has changed default settings
 Improvement: Network event log has changed default settings
 New: B2FOR+ and B4FOR+ have been added to the diagnostic slave page

********************************************************************************

Version 1.302 (build 1)  -- RELEASE APRIL 2019 --

 Fix: Some times message recording created a corrupted file.
 Improvement: Added module & device tag names to events.
 Improvement: Links on the web interface follow the user account rights.
 New: Relay, Email & log events on Profibus DP idle level.
 New: Measurement time is displayed on the top of each web page. It can be reset with 'clear all data'.
 New: ComBricks can be remotely update via the NCI tool (Requires firmware version 1.302 or higher in the Head Station).

********************************************************************************

Version 1.301 (build 1)  -- RELEASE JANUARY 2019 --

 Diagnostic slaves of ProfiHubs (ProfiHub firmware 2.0) can be detected. Detailed information is exported to the webpage & SNMP.
 'ComBricks' and 'Head Station' are correctly spelled throughout the firmware.
 Fix with the German language file, where a translation was inconsistent.

********************************************************************************

Version 1.300 (build 0)  -- RELEASE OCTOBER 2018 --

 Fix: On the scope modules the TERM and/or MIN leds show incorrect value (bug introduced in V1.299)

********************************************************************************

Version 1.299 (build 9)  -- RELEASE OCTOBER 2018 --

 New: Maintenance button has been added to put the ComBricks into maintenance mode. This will pause the logging of events.
 New: SNMP Traps on physical measurements have been added: DP (Bargraph, idle level) & PA (Bargraph, jitter, DC measurements).
 Fix: Clear All Data now also clears Scope Images saved on the SD-card & pending Email/Log events.
 Improvement: LEDS of the PA-coupler/link module are shown on the module specific web page.
 Improvement: Live list can be reset without resetting the IdentNrs.

Internal:

 New: Diagnostic slave read-out. has been added but not visible to the user.
 New: Message recording overview file has been added. this functionality is disabled for now.

********************************************************************************

Version 1.298 (build 0)  -- RELEASE MAY 2018 --

 Fix: Several fiber optic ring module corrections.
 New: SNMP trap can be sent when the head station has a system-failure or io-failure.
 Improvement: The internal temperature of the head station has been added to system-failure event.

********************************************************************************

Version 1.297 (build 1)  -- RELEASE April 2018 --

 New: Head Station now supports SNMP traps.
 New: SNMP trap can be sent when the head station starts/restarts it software.
 New: SNMP trap can be sent on Power module events (PWR-6A, 101-230010, Hardware revision V1.4 and newer).
 Improvement: Log/Email/Output events can be activated for Power module (PWR-6A, 101-230010, Hardware revision V1.4 and newer).

********************************************************************************

Version 1.296 (build 3)  -- RELEASE January 2018 --

 Improvement: Output control now supports 20 configurations.
 Improvement: Transceiver has been improved to correct deviation on timing of incomming signals

********************************************************************************

Version 1.295 (build 1)  -- RELEASE October 2017 --

 Fix:  (issue CHS-71/TS10355) Webpage shows 'Not found' error message without appartent reason.

********************************************************************************
Version 1.294 (build 11)  -- INTERNAL RELEASE FOR HE+ --

 Fix:  (issue CHS-1/8983) Message recording; the messages before and after trigger are checked agains stricter limits.
 Fix:  Several bug fixes in the IP stack & File system
 New:  Modifications for ComBricks HE+. Normal ComBricks and HE+ use the same Head Station package.
 New:  Web, Streaming and CommDTM TCP-ports are configurable.

********************************************************************************

Version 1.293 (build 4)  -- RELEASE November 2016 --

 New:  Events can be sent to four configurable email groups.
 Fix:  Some German translations were inconsistent.

********************************************************************************

Version 1.292 (build 2)  -- RELEASE September 2016 --

 New:  Output control has been extended with the function to only enable a relay/output during an error.
 Fix:  The NTP server could time was not handled correctly (error was introduced in 1.291)
 Fix:  The Ext. Diag. statistic was not resetted correctly.

********************************************************************************

Version 1.291 (build 4)  -- RELEASE March 2016 --

 Fix:  Message recording files were not always deleted properly.
 Fix:  SNMP returned incorrect maximum statistics values.
 Fix:  Downloading the log from the web page failed some times.
 Fix:  Station lost sometimes counted double.
 Fix:  The CommDTM master sometimes did not respond correct to an FDL status message.
 Fix:  Time zone list has been completed with all used time zones.

********************************************************************************

Version 1.290 (build 8)  -- RELEASE November 2015 --

 New:  The menu layout can be adjusted by an administrator, so users can only see/access certain pages.
 Fix:  Green DX background in live list sometimes disappeared.
 Fix:  Sometimes the lost statistic was not counted correctly due to illegals on the Profibus network.
 Fix:  Some events we not generated on Ext. diag statistic.
 Fix:  Downloading PDF files from the Head Station did not work correctly on some browsers.
 Fix:  Sometimes the head station did not respond on Ethernet.
 Fix:  Output control did not respond to baudrate changes.
 Fix:  Output control some times did not display the correct configuration after reloading the page.

********************************************************************************

Version 1.289 (build 0)  -- RELEASE May 2015 --

 New:  Support for Fiber Optic ring modules (SM, MM & XM).
 New:  Signal and ring events for Fiber Optic ring module.
 Fix:  Some phrases were not translated.
 Fix:  Fiber Optic fix for 6Mbit networks.
 Fix:  Downloads link in the menu was not visible.

********************************************************************************

Version 1.287 (build 0)  -- RELEASE ?? January 2015 --

 Fix: issue salesforce 6042, on webpage update license, streaming Profitrace on yes in stead of 1

********************************************************************************


Version 1.287 (build 6)  -- RELEASE ?? January 2015 --

 New:  Support for Foundation Fieldbus module.
 New:  Livelist for Foundation Fieldbus.
 New:  Scope images/bargraph for Foundation Fieldbus.
 New:  Physical network events for Foundation Fieldbus.

********************************************************************************

Version 1.286 (build 8)  -- RELEASE ?? November 2014 --

 New:  Option to automatically save scope images and bargraphs to the SD card
 Fix:  File system library has been updated.
 Fix:  Streaming stability has been improved.
 Fix:  Fixed spurious logging of changed baudrate in the network log for PA cards. 

********************************************************************************

Version 1.285 (build 2)  -- RELEASE 31 July 2014 --

 Fix:  Support for Asian languages has been added.
 Fix:  SD-card functions have better error handling.

********************************************************************************

Version 1.284 (build 2)  -- RELEASE 18 July 2014 --

 Fix:  Fix in CommDTM master error handling.
 Fix:  Head station temperature was not displayed correctly if the temperature was below 0 Celsius.
 Fix:  If an erroneous SD-Card was inserted at start-up, the Head station would not start-up correctly.

********************************************************************************

Version 1.283 (build 2)  -- RELEASE 12 June 2014 --

 New:  An administrator can clear all current information in the "Device management".
 Fix:  Fixed an unexpected DP-V1 abort during CommDTM communication.
 Fix:  Fixed several CommDTM DP-V1 bugs.
 Fix:  Fixed a bug regarding the SMTP (email) client.
 Fix:  A long tag name in the livelist is broken into two words so all text is visible in the cell.

Internal:
 Fix:  Fixed a bug regarding password management, where an unauthorized visitor could retrieve the admin password.

********************************************************************************

Version 1.282 (build 6)  -- RELEASE (PHOENIX CONTACT) 7 MAY 2014 --

 Fix:  Unexpected DP-V1 abort during CommDTM communication.
 Fix:  Fixed several CommDTM DP-V1 bugs.

********************************************************************************

Version 1.281 (build 5)  -- RELEASE MARCH 2014 --

 Fix:  In certain cases the oscilloscope images could not be retrieved from the modules.
 Fix:  With certain (exotic) busparameters the CommDTM master would not get in the token-ring.

********************************************************************************

Version 1.280 (build 5)  -- RELEASE FEBRUARI 2014 --

 Fix:  When activating DHCP on the webserver, the manually entered IP addresses are not checked.
 Fix:  In certain cases an administrator could not save settings.

********************************************************************************

Version 1.279 (build 7)  -- RELEASE 31 DECEMBER 2013 --

 New:  Network config has been extended for PA-Link switches.
 New:  PA-Link device info webpage has been extended with PA-Link settings.
 Fix:  The DHCP host-name was not always sent correctly.
 Fix:  The redundant state of Profibus channels was not always displayed correctly on the channel list webpage.

********************************************************************************

Version 1.278 (build 11)  -- RELEASE 11 NOVEMBER 2013 --

 Improvement:  SNMP agent compatibility improved.
 Fix:  The Head Station Device name is limited to alphanumeric characters.
 Fix:  The Message record settings are disabled if Message recording is active.
 New:  An NTP server can be set-up in the general config.
 Improvement:  The event config has been extended with events on Fiber optic signal strength.
 Improvement:  The output control config has been extended with events on Fiber optic signal strength.
 Fix:  The baudrate is shown on the webserver if a Head Station has a 1A license.
 Improvement:  The event config has been extended with events on Head station system failures.
 Improvement:  The output control config has been extended with events on Head station system failures.
 Fix:  Busparameter fix in FDL master.
 Fix:  Improvement in webserver stability.

(interne referentie)

 New:  Samenvattingspagina voor de duurtest. (http://ip-address/duration_test.htm)
 Fix:  Verbetering in betrouwbaarheid statistieken (gevonden tijdens duurtest)

********************************************************************************


Version 1.277 (build 7)  -- RELEASE 12 AUGUSTUS 2013 --

 New:  The statistics view also displays livelist background color.
 New:  Bargraph values can be read out using SNMP (see updated SNMP-MIB file).
 New:  New Fiber Optic module is supported.
 Fix:  If the head station has an output-control configuration, write access to the configured module is blocked for other modules.
 Fix:  The CommDTM master now supports 128 independent DP-V1 connections.
 Fix:  Head station bitmap image has been updated in the channel list.
 Fix:  Bargraph values did not become inactive if the stations are transferred to another channel in the same network.
 Fix:  Bargraph SCOPE-repeater signal did not become inactive if the SCOPE-repeater itself is not forwarding messages.
 Fix:  Some visual fixes in the channel-list webpage.
 Info: Languages other than English and German have to be copied manually in the 'trans' directory of the SD-Card in order to be used. 
				They can be downloaded separately for the Procentec website.

********************************************************************************

Version 1.276 (build 3)  -- RELEASE 17 JUNI 2013 --

 New: Czech language added.
 Fix: The user was not able to select 'N/C' in the Network Config, when a license with less than 4 networks was active.
 Fix: CommDTM bugfix, some DP-V1 Messages did were not transferred to the network.

********************************************************************************

Version 1.276 (build 1)  -- RELEASE TUSSENDOOR INTERN! --

 New: Czech language added
 Fix: With less than 4 available networks, the user was not able to select 'N/C' in the Netowrk Config.

********************************************************************************

Version 1.275 (build 7)  -- RELEASE 8 APRIL 2013 --

 New: Failsafe functionality has been added for the PND-001 and PBS-001 modules.
 Fix: CommDTM bug fixed.

(interne referentie)

 Improvement: Na het initieel programmeren van een licentie, hoeft de combricks niet opnieuw opgestart te worden.
 Fix: Het output geheugen van een module wordt ge-cleard als de module eruit wordt getrokken zodat de nieuwe 
       module met op '0' genitialiseerde outputs begint (bv: relais module -> output module)
 Fix: Bovenstaande CommDTM bug kwam voor als er een busparameter n connect request vlak achter elkaar verzonden
       werden naar de CB-HS. De connect request kwam dan niet goed door en werd niet afgehandeld.

********************************************************************************

Version 1.274 (build 2)  -- RELEASE Several bugs/features --

 New: A Live List legend has been added.
 Improvement: On the webpage of the Power Module the meaning of the Overload LED has been changed to a more clear description.
 Improvement: After startup the log is directly saved to the Micro-SD-card to save the log messages produced at startup.
 Improvement: The DC-Noise measurement has been added to the PA-Measurements webpage.
 Fix: The Tag-names of module/slots and Live List stations can now only be changed by administrators.
 Fix: CommDTM TCP communication bug fixed.

********************************************************************************

Version 1.273 (build 6)  -- BETA RELEASE SD-CARD HANDLING --

 Fix: The firmware handles faulty SD-Cards better and lights the SYSF-LED in case of problems.

********************************************************************************

Version 1.272 (build 4)  -- BETA RELEASE COOKIE BUG --

 Fix: Certain HTTP requests were not handled correct.

********************************************************************************

Version 1.272 (build 2)  -- BETA RELEASE ALIVE-EMAIL BUG --

 Fix: Enabling the Alive-email caused the Head-Station to crash and reboot.
 Fix: In certain situations the Email addresses were not displayed correcly in an Email.

********************************************************************************

Version 1.271 (build 5)  -- BETA RELEASE 8DI --

 New: 8DI module is supported.
 Fix: Some module images have been updated.

********************************************************************************

Version 1.270 (build 4)  -- BETA RELEASE IS-SCOPE --

 New: IS-Scope module is supported.

********************************************************************************

Version 1.269 (build 6)  -- RELEASE NOVEMBER 2012 / SPS2012 --

(COMbricks head station)

 New: German language has been added.
 Fix: Tag names for slots and livelist stations were not deleted on a factory reset.
 Fix: When making a backup or restoring the settings to/from SD-card, the usermessage and tag-name files are also copied.
 Fix: Javascript libraries have been updated for compatibility with Internet Explorer 9.
 Fix: If no SD-card was present on the system, the Head-Station info page displayed false capacity/free space values.
 Fix: On the 'Output control' web page, the module tag names were mixed up.
 Fix: On the 'PA-measurements' web page the jitter color has been changed from red to blue.
 Fix: On the 'PA-coupler info' web page, the used current is now displayed in mA.

********************************************************************************

Version 1.267 (build 69)  -- RELEASE OKTOBER 2012 --

(COMbricks head station)

 New: The timeout of livelist station can be adjusted in the Network config.
 New: Profibus slave module is supported.
 New: Profibus PA-coupler module is supported (including events on E-mail, Log and Output-controls).
 New: Tag names for slots have been added so users can give them understandable names (menu->Tag-name config).
 New: Tag names for livelist-stations have been added so users can give them understandable names (menu->Tag-name config).
 Improvement: On SNMP the livelist values can be retrieved as an SNMP-TABLE at 1.3.6.1.4.1.38925.1.1.2.8 (please use the newest SNMP-MIB for this feature).
 Fix: When running on a network with very large slot times, the statistics did not count correct.
 Fix: When doing a DHCP request, the COMbricks headstation will send its device-name with the request.
 Fix: When creating a directory on FTP, the return code was different from the FTP-standard.

(SNMP MIB)

 Improvement: On SNMP the livelist values can be retrieved as an SNMP-TABLE at 1.3.6.1.4.1.38925.1.1.2.8

(interne referentie, kleine wijzigingen, uitleg over bovenstaande)

 vertaalbaar maken van de head station is reeds aanwezig, dit zorgt voor een iets langere opstarttijd. opstarttijd zou rond de 40-50 seconden moeten zijn.

********************************************************************************

Version 1.266 (build 29)  -- RELEASE 10 AUGUSTUS 2012 --

(COMbricks head station)

 New: The SD-card capacity, free space and used space are displayed on the 'Head Station info' web page.
 New: The default 'start page' of the webserver can be changed.
 New: The channels on a Profibus repeater can be disconnected from a network.
 New: A periodic alive-email can be sent on a user specified interval.
 New: An email/log-entry can be sent/added if one of the redundant powers connected to the COMbricks Head Station fails.
 New: A relay or output can be switched if one of the redundant powers connected to the COMbricks Head Station fails.
 New: An email/log-entry can be sent/added if one of the redundant profibus channels fail.
 New: A relay or output can be switched if one of the redundant profibus channels fail.
 Improvement: At the 'bargraph' web page of the SCOPE modules, there is a text explaining the measurement method.
 Improvement: The 'channel list' web page also displays redundant profibus channels.
 Fix: The idle line voltage of a SCOPE module displayed an incorrect value when the A & B-Line were shortend together.
 Fix: When entering a password on the 'password config' web page, asterisk signs (*) are displayed.
 Fix: FDL status request are exluded from retry mechanism.

(Discovery tool, head station firmware 1.266 required for some features)

 Improvement: The Discovery tool has the ability to find a free IP-address when changing the IP-address of a COMbricks Head Station.
 Improvement: The Discovery tool has the ability to set a COMbricks Head Station to DHCP.
 Improvement: The COMbricks Head Station Device-Name is displayed in the Discovery tool.
 Improvement: The Discovery tool will display a warning message when browsing to a COMbricks Head Station's webserver, if the IP-address is not in the same range as the user's PC.

(interne referentie, kleine wijzigingen, uitleg over bovenstaande)

 Improvement: In het info scherm van de PA module, de stroom in mA weergeven. (ondersteuning PA is ook verder uitgebreid)
 Discovery tool has a new icon and bitmap image of the COMbricks
 Addressing of coupler ram inside the FPGA is not OK
 

********************************************************************************

Version 1.265 (build 9)  -- RELEASE X JUNI 2012 --

 New module is supported: Power module.
 Fix: Better support for new webbrowsers (Firefox 12).
 Fix: Bug fix in CommDTM-stack.
 Fix: Values in 'other scope settings' table were not always displayed correct.
 Fix: In a specific situation, when manually changing an output in the 'output control' webpage, the output did not respond.
 Fix: 'Reset this statistic' on the statistics page did not work correct.

(interne referentie, kleine wijzigingen, uitleg over bovenstaande)
 Fix: Ramcode signature zit op vaste plek achteraan de bin-file
 Fix: In firefox versie 12 is er geen 'timeout' element voor het XmlHttpRequest object.
 Fix: In de CommDTM-stack, is foutafhandling verbeterd
 Fix: Bij de output control, als je een instelling wijzigde, en dan een output op manual-on of -off zet, dan reageerde de output niet.
 Fix: Bij de scope beelden wordt de voltage schaal aangepast a.h.v. de schaal van de gebruikte ADC

********************************************************************************

Version 1.264 (build 30)  -- RELEASE 10 APRIL 2012 --

 New: SNMP functionality has been added.
 New module is supported: Profinet IO-Device.
 New module is supported: 2ch Fiber Optic
 New module is supported: NONPB SCOPE repeater module.
 Improvement: The 'message recorder' now supports up to 1000 files per network to record.
 Improvement: The modules are found much faster by the Head station.
 Improvement: Scope config page has been updated for the NONPB SCOPE repeater.
 Improvement: E-mail addresses can be seperated by a ';' as well as by a ','.
 Improvement: Device-Name has been added to identify COMbricks headstations.
 Improvement: The 'Channel list' web page displays a more realistic map of the COMbricks modules and connected devices.
 Improvement: The 'info web pages' display the errors in RED text color.
 Fix: The 'CommDTM server' was some times assigning the wrong master to an incomming connection, when using more than one connection.
 Fix: The 'CommDTM master' was some times comming on to the bus before it received a token.
 Fix: The 'Channel list' web page: when devices on a channel were switched over to another network/channel, the devices on that channel were not displayed correctly.

(interne referentie, kleine wijzigingen)
 Improvement: Code wordt nu ook vanuit SDRAM uitgevoerd.
 Improvement: Debug log web pagina is gedetailleerder.
 Improvement: The 'headstation info' web page displays the operational voltage.
 Improvement: Nieuw favicon op de webpagina.
 Improvement: de HTML pagina's bevatten tags waarmee ze niet door zoekmachines gescand worden.
 Improvement: Output control task has been optimized (performance).
 Improvement: Output control task / Notify task (email & log) have been modified for scope-card specific bargraph-MIN values.
 Improvement: module enumeration task has been optimized (performance).
 Fix: er is een bug gefixt waardoor HS met een serienummer hoger dan 999 mogelijk hun serienummer verkeerd weergaven.
 Fix: copyright stond nog op 2011, ipv 2012
 Fix: de kleur van de scope lijn werd ongewild veranderd, bij het saven van de settings.

Note: Output control has been optimized. BETA TESTERS: Please test it firmly!
Note: Message recorder has been updated. BETA TESTERS: test it firmly, also with small & full SD-cards!
Note: Some program code runs in SDRAM now. BETA TESTERS: test the whole software firmly!

********************************************************************************
Version 1.262 (build 60) --RELEASE BASED ON 1.261--

 Fix: SD-Card bug fixed
 Fix: Scope images were not always displayed on the web page.

********************************************************************************
Version 1.262 (build 31) --BETA--

 New: SNMP functionality has been added.
 Improvement: The e-mail addresses can be seperated by a ';' as well as by a ','.
 Improvement: Device-Name has been added to identify COMbricks headstations.
 Improvement: The 'channel list' web page displays a more realistic map of the COMbricks modules and connected devices.
 Improvement: The info web pages display the errors in RED text color.
 Fix: Scope images were not always displayed on the web page.
 Fix: The CommDTM server was some times assigning the wrong master to an incomming connection.

(intern)
 Improvement: Code wordt nu ook vanuit SDRAM uitgevoerd
 Improvement: Debug log web pagina is gedetailleerder
 Improvement: The 'headstation info' web page displays the operational voltage

********************************************************************************
Version 1.261 (build 37) --BETA--

 Fix: The CommDTM server was some times assigning the wrong master to an incomming connection.

********************************************************************************
Version 1.261 (build 36)

 New: Comm-DTM functionality has been added (2 masters).
 Fix: The idle line voltage of the SCOPE-repeater was not displayed correct when there was no baudrate detected on the network.
 Improvement: SCOPE-repeater TERM-LED MIN- and MAX-voltages can be set manually on the SCOPE-config page.
 Improvement: 'Device name' and 'System contact' have been added in the device settings, it will be sent along with E-mails.
 Improvement: The actual IP-settings are displayed on the IP-config page.
 Improvement: The telnet interface has been updated (display of data has been improved)

********************************************************************************
Version 1.260 (build 20)

 New: Oscilloscope modules are supported (last/min/max images, error images, bargraph)
 Fix: Time-out of data-exchange slave is now set to 5 seconds.

********************************************************************************

Version 1.255 (build 14) -- testversie voor Fedor & Distributeursmeeting

 New: Oscilloscope modules are supported

********************************************************************************

Version 1.254 (build 38)

(intern)
 Fix: Masterlost bug in output control has been fixed. (comapred to 1.254.37

********************************************************************************

Version 1.254 (build 37)

(intern)
 New: An info page for the scope-module has been added.(disabled in release)
 New: An info page for the relay-module has been added.
 Improvement: COMM-DTM server has been improved, ready for testing. (disabled in release)
 Improvement: Debug page "system info" has more detailed info about head-station errors.
 New: Acyclic- and mailbox-functions have been added for communication between submodules.
 Improvement: Fpga communication now works on a 1ms timer
 Improvement: Enumerating modules has a retry mechanism built in.
 Improvement: Memory (LED space) of repeater modules is blocked for other modules
 Fix: Doc-dir check in de headstation was niet goed geimplementeerd. is nu gefixt.

(publiek)
 New: Output control has been added. The relay on the Head station can be controlled manually, on a specific time or on Profibus events.
 New: A list of connected clients, and the service they are using, is displayed in the status-webpage. 
 New: A device channel list has been added. This page displays all connected Profibus devices (with livelist colors) and on what channel of the COMbricks repeaters they are connected.
 Improvement: The email error messages are more clear about what is wrong.
 Improvement: The speed of enumerating modules has been increased.
 Improvement: When restoring settings from the SD-card, the new IP-address is automatically applied.
 Improvement: When applying factory defaults, the settings-backup on the SD-card is not removed.
 Bug fix: In the repeater status page, the number of stations on the channels was not always correctly displayed.
 Bug fix: Ext diag statistic did not always display the correct value.

********************************************************************************

Version 1.253 (build 52)

 Bug fixed in production test: relay was not controllable by the test-sw in version 1.253.51

********************************************************************************

Version 1.253 (build 51)

(intern)
 Work in progress: Oscilloscope-card preparations (oscilloscope images and bargraph)
 Work in progress: 2 FDL-masters have been added, and CommDTM functions can be executed with them.
 Improvement: Webserver now supports cookies!
 Improvement: Security is improved, password is sent encrypted over the web connections.
 Improvement: Security is improved, password is sent as cookie variable and not as URL-parameter.
 Improvement: Webserver now supports larger buffers, and longer path names.
 Improvement: IP-window size and buffers have been updated.
 Improvement: IP-stack/Webserver source code has been added.
 New: FTP dummy-file is available on \nor$1$\ when using procentec login account.
 New: Debug log has been added as webpage (debug_log.htm).

(publiek)
 New: Streaming telegrams to Profitrace via ethernet.
 New: Repeater modules have their own status page.
 Fix: In Firefox, the warm restart function did not work 2 times after one another.
 Fix: The FTP server was not able to rename directories.
 Improvement: Caching is enabled for the webserver files, loading web pages should be faster now.
 Improvement: Handling of the periodic browser-data has been improved.
 Improvement: Headstation current limit has been changed from 2.5A to 2.8A.
 Improvement: Headstation current overload (>3.0A) causes it to shutdown and retry after a couple of seconds.


********************************************************************************

Version 1.252 (build 36)

 Work in progress: Oscilloscope-card preparations (oscilloscope images and bargraph)
 Work in progress: 2 FDL-masters have been added, and CommDTM functions can be executed with them.
 Work in progress: Streaming telegrams to Profitrace.

 New: A download area has been added on the website, it is only visible if suitable files are present on the micro-SD-card.
 New: The triggered busmonitor can now automaticly re-trigger after an event.
 New: The triggered busmonitor displays the result of the previous saved trigger-event.
 Improvement: IP-stack has been updated.
 Improvement: A bug in the module enumeration has been fixed.
 Improvement: On the website, head station serial number is displayed on the license page.
 Improvement: On the website, event config has been moved to the Profitrace-OE section of the menu.
 Improvement: Optimizations in the javascript.
 Improvement: Javascript timeout has been fixed.
 Improvement: Javascript support for old browsers (IE6.0) has been improved.
 Improvement: Bug in SD-ram check, now really checks the SD-ram of the headstation. If an error occurs, the SF-LED is lit.

********************************************************************************

Version 1.250

 Improvement: Several bugs fixed
 Improvement: Several optimizations

********************************************************************************

Version 1.249

 NEW: Module diagnostics directly from the status screen
 Improvement: Consistent written menu items
 Improvement: Better license discriptions in the licence update screen
 Improvement: More FTP commands
 Improvement: More log entries

********************************************************************************

Version 1.241

 NEW: First release